The Phantom® Premium™ haptic devices fulfill the requirements of a vast range of research and commercial applications

Phantom Premium Technical Specifications

Property

Premium 1.5

Premium 1.5/6DOF

Premium 1.5 High Force

Premium 1.5 High Force/6DOF

Workspace
Translational

15 W x 10.5 H x 7.5 D in
381 W x 267 H x 191 D mm

15 W x 10.5 H x 7.5 D in
381 W x 267 H x 191 D mm

Rotational
Yaw
Pitch
Roll


297 degrees/5.18 radians
260 degrees/4.54 radians
335 degrees/5.85 radians


297 degrees/5.18 radians
260 degrees/4.54 radians
335 degrees/5.85 radians

Range of motion

Lower arm movement pivoting at elbow

Lower arm movement pivoting at elbow

Nominal position resolution
Translational

860 dpi/0.03mm

3784 dpi/0.007mm

Rotational
Yaw & Pitch
Roll

0.0023 degrees/0.00004 radians
0.0080 degrees/0.00014 radians

0.0023 degrees/0.00004 radians
0.0080 degrees/0.00014 radians

Maximum exertable force and torque at nominal position (orthogonal arms)
Translational

1.9 lbf/8.5 N

8.4 lbf/37.5 N

Rotational
Yaw & Pitch
Roll

73 oz-in/515 mNm
24 oz-in/170 mNm

73 oz-in/515 mNm
24 oz-in/170 mNm

Stiffness

20 lbf in-1
3.5 N mm-1

20 lbf in-1
3.5 N mm-1

Force feedback
(6 degrees of Freedom)

x, y, z

x, y, z, Tx, Ty, Tz

x, y, z

x, y, z, Tx, Ty, Tz

Position sensing/input
(6 degrees of Freedom)

x, y, z, roll, pitch, yaw

x, y, z, roll, pitch, yaw

Interface

Parallel port

Parallel port

Optional end effectors

Encoder gimbal

Thumb pad (pinch), scissors

HF Encoder gimbal

Thumb pad (pinch), scissors

Request a Demo of Phantom Premium Haptic Devices

Would you like to receive special offers, product updates, and event news from 3D Systems? By clicking "Yes", you agree to receive follow-up email or phone communications from 3D Systems or our partners. You can also choose to opt out of communications at any time. Please click here to view our Privacy Policy or click here to manage your Preferences.